HOW TO CALCULATE BEARING CAPACITY OF SHALLOW FOUNDATION IN SAND FROM SPT VALUES OR N-VALUES (IS-6403)
STEP-BY-STEP PROCEDURE FOR CALCULATION OF BEARING CAPACITY FROM STANDARD PENETRATION TEST VALUES OR N-VALUES
STEP-1
Perform standard penetration test on the location for which you want to calculate bearing capacity. This is done as per standard procedure given in IS-2131. Standard penetration test must be done at every 75 cm in vertical direction.
STEP-2
Decide the depth, width and length of foundation for initial calculation. This is a trial and error process. In the first attempt, you can never get the exact size of foundation which will satisfy all of your needs.
STEP-3
Apply necessary corrections to the standard penetration test values. Calculate the cumulative average value of corrected SPT values from the base level of foundation to a depth equal to 2 times the width of foundation.
STEP-4
Correlate the above cumulative average SPT value with the fig given below to find out the corresponding angle of shearing resistance (ϕ).
STEP-5
Calculate effective surcharge at the base level of foundation by multiplying the effective unit weight of soil with the depth of the foundation i.e.
q = ϒ*Df
Where,
q = Effective surcharge at the base level of foundation, in kgf/cm2
ϒ = Unit weight of soil, in kgf/cm3
Df = Depth of foundation, in cm
STEP-6
For the angle of shearing resistance value (ϕ) as calculated in step-4, find out the corresponding values of bearing capacity factors (i.e. Nq & Nϒ) from the table given below. For the intermediate values of ‘ϕ’, make linear interpolation.
STEP-7
Calculate shape factors (i.e. sq & sϒ) using formula given below.
Where,
B = Width of foundation, in cm
L = Length of foundation, in cm
STEP-8
Calculate depth factors (i.e. dq & dϒ) using following formula.
dq=dϒ=1 (for ϕ < 100)
dq = dϒ = 1+0.1(Df/B)(Nϕ)1/2 (for ϕ>100)
Nϕ is calculated using following formula
Nϕ = tan2[(π/4)+(ϕ/2)]
STEP-9
Calculate inclination factors (i.e. iq & iϒ) using the formula given below
Where,
α = Inclination of the load to the vertical in degrees
ϕ = Angles of shearing resistance in degrees
STEP-10
Calculate the correction factor for location of water table using the following formula
W’ = 0.5+0.5[Dw/(Df+B)]
Where,
W’ = Correction factor for location of water table
Dw = Depth of water table, in cm
Df = Depth of foundation, in cm
STEP-11
Using the equation given below calculate the net ultimate bearing capacity.
Where,
qd = Net ultimate bearing capacity of foundation, kgf/cm2
q = Effective surcharge at base level of foundation, in kgf/cm2 (Refer step-5)
Nq & Nϒ = Bearing capacity factors (Refer step-6)
sq & sϒ = Shape factors (Refer step-7)
dq & dϒ = Depth factors (Refer step-8)
iq & iϒ = Inclination factors (Refer step-9)
W’ = Correction factor for location of water table (Refer step-10)
B = Width of foundation, in cm
ϒ = Bulk unit weight of foundation soil, in kgf/cm3.
Simple method to calculate the depth of shallow foundation
ReplyDelete